Flatpack2 5U-7U Integrated
The combination of high efficiency, power density and reliability makes the Flatpack2 a product family that truly stands out and provides unparalleled network availability.The versatility of the Flatpack2 rectifier in combination with advanced control and monitoring means that it can be used in a wide variety of DC telecom applications, both for fixed grid and alternative energy across the globe.
Flatpack2 5U-7U Integrated
The combination of high efficiency, power density and reliability makes the Flatpack2 a product family that truly stands out and provides unparalleled network availability.The versatility of the Flatpack2 rectifier in combination with advanced control and monitoring means that it can be used in a wide variety of DC telecom applications, both for fixed grid and alternative energy across the globe.
closeOverview
Flatpack2 5U-7U Integrated
The 4U distribution is designed to meet the demand for compact and flexible DC power solutions. It is based on building blocks and has a variety of configurations depending on power, controller, battery section and load section.
Pluggable battery breakers and DIN mounted load breakers ensures easy configurability as well as “in field” replacement. The power system has two controller options, Smartpack2 or Smartpack S which both has all the functionality required in present and future applications.
Pluggable battery breakers and DIN mounted load breakers ensures easy configurability as well as “in field” replacement. The power system has two controller options, Smartpack2 or Smartpack S which both has all the functionality required in present and future applications.
Key features
- Complete system
- Smartpack2 or Smartpack S controller
- Hot pluggable modules
- 19”/4U distribution chassis with hinged front door
- Upto 8x battery breakers
- LVBD
- Upto 20x load breaker positions
- LVLD (optional)
- Global approvals
Technical Data
Input
Max input AC Voltage
305 VAC
Mains configuration
230VAC Single phase;230VAC 3 phase (Δ);230/400VAC 3 phase (Y)
DC Output
Current (maximum)
500 ADC
Max voltage
60 VDC
Max power
24 kW
Battery Distribution
Breaker positions up to
8
Breaker rating up to
250 A
LVBD
Yes
DC Load Distribution
Breaker positions up to
20
Breaker rating up to
125 A
LVLD
Yes
Other
Operating temperature
-40 - 70 °C
Mounting Type
Rack 19”
Dimensions
Dimensions WxHxD (mm)
482 x 380 x 311 mm
Dimensions WxHxD (inch)
19 x 14,96 x 12,3 "
Design Standards
Ingress Protection (IP)
20
Downloads (4)
-
Datasheet Flatpack2 5U - 7U Integrated
- Version 6
- 404 kB
- Document number: M20405.401.DS3
-
Datasheet Flatpack2 5U - 7U Integrated - Russian
- Version 5
- 530 kB
- Document number: DS - M20405.401.DS3
-
FP2 48V/300A 4U distribution with Smartpack2
- Version 5
- 90 kB
- Document number: M20405.401.DS3
-
FP2 48V/300A 4U distribution with Smartpack2 - Spanish
- Version 5
- 84 kB
- Document number: M20405.401.DS6
Flatpack2 5U-7U Integrated
The 4U distribution is designed to meet the demand for compact and flexible DC power solutions. It is based on building blocks and has a variety of configurations depending on power, controller, battery section and load section.
Pluggable battery breakers and DIN mounted load breakers ensures easy configurability as well as “in field” replacement. The power system has two controller options, Smartpack2 or Smartpack S which both has all the functionality required in present and future applications.
Pluggable battery breakers and DIN mounted load breakers ensures easy configurability as well as “in field” replacement. The power system has two controller options, Smartpack2 or Smartpack S which both has all the functionality required in present and future applications.
Key features
- Complete system
- Smartpack2 or Smartpack S controller
- Hot pluggable modules
- 19”/4U distribution chassis with hinged front door
- Upto 8x battery breakers
- LVBD
- Upto 20x load breaker positions
- LVLD (optional)
- Global approvals
Request a quote